|
Burner Control
|
|
- For the startup and supervision of single or 2-stage forced
draught gas/oil burner of small to medium capacity in
intermitent operation.
- Gas burner control
- Oil burner control |
|
Oil Burner Control |
|
- Microcontroller based oil burner control for the suppervision
start up and control for single stage burner.
- For single stage or two stages burner
|
|
Gas Burner Control |
|
- Universally applicable for multistage or modulating
gas burner with pilot burner connection and ionization.
|
|
Oil Burner Control |
|
- Universally applicable for multistages or modulating
oil burner with air pressure check and air damper control. |
LAE1 |
Burner Control |
|
- Universally applicable for multistages or modulating oil burner |
AGK11,AGK65,AGK66,AGK67
LGB ,LMG,LOA,LMO |
Bases for small burner controls
|
|
- Accessoories for connecting burner controls of capacity to combustion plant.
- The AGK ... are for use in connection with the following types of burner controls
|
TQG1 |
Electronic ignition transformer |
|
- For single-pole igntion of atmospheric gas burners.
- Pri. 220Vac. ,50/60Hz. Sec. 14kV. |
QRA10 |
UV Detectors
|

|
.
- Flame detectors for use with burner controls, for the supervision of gas flames and oil flames. |
QRA2 |
UV Detectors |
|
- Wtih this type of flame supervision, the UV radiation emitted by gas or oil flames is used to generate the flame signal. |
QRB1 ...A |
UV Detectors |
|
- With soft plastic plug. |
QRB3 |
Photoresistive detectors
|
|
- Is supplied with a protective tube of 17mm diameter.
Tihs type of detector is always secured witha flange and a clamp |
RAR ,LAL ..., LAE1, LOK ... |
Selenium photocell detectors |
|
- Selenium photocell detectors with this type of oil flames in the visible band of the light spectrum is used to generate a flame signal.
- use with burner controls type |
SQN30,SQN31,SQN41,
SQN 70 .,71 ., 74 .,75 ., |
Air damper actuators |
|
-For burner air dampers, air/gas ratio control, etc.
- anti-clockwise rotation, up to 3Nm.
- clockwise rotation, up to 3Nm.
- clockwise rotation, up to 6Nm.
- with torques up to 2.5Nm. with two limit and two auxiraly.
- running time 4...30s
- running time 4...60s |
SQM |
|
|
- The reversible damper motors are suitable for 2-wire control with controllers or switching units with changeover contact.
|
SKD62 + VVF31 ... |
Electric actuator with two or three-way valve
|
|
- With stroke-console and manual knob for two-way and with controllers or switching units with changeover contact. |
SKP10 ... / SKP20 ... |
Electrohydraulic actuators
|
|
- For safety shut off valves. Two-stage or with integrated constant pressure governor.
|
VRF10,VHF10 |
Valves for Biogases and Recycling gase |
|
- Normally closed type, operate as safety shutoff valves.
- Can be combined with actuators type SKP ... or SQX ...
- ( DN 40 ~ 80 ) Pmax 600 mbar
- ( DN 80 ~ 125 ) Pmax 300 mbar |