Gas filter
|
|
Suitable for filtration of thr fuel gas and combustion air suplly
to all gas consuming appliances
Pmax 1~ 6 bar ( Rp1/2 ~ 2 1/2, DN40 ~ 250 ) |
GDJ 15... ,GDJ 20 to 40...GDJ 50...
|
Governors for gas |
|
To control gas and air inlet pressure for gas burners and appliances
in industry and for heating purposes.
Inlet pressure 400mbar /Outlet pressure ranges
- 2 ~ 55mbar ( Rp1/2 )
- 5 ~ 160mbar ( Rp3/4 ~ 1 1/2 )
- 5 ~ 100mbar ( Rp2 ) |
F 40 to 150F02,VGBF 15...,
VGBF 40 to 250... |
|
|
Governor for gaseous media, to be fitted to all types
of gas consuming appliances
Inlet pressure 0.2bar /Outlet pressure ranges
- 5 ~ 350mbar ( DN40 ~ 150 )
Inlet pressure 1~4bar /Outlet pressure ranges
- 5 ~ 350mbar ( Rp1/2 ~ 1 1/2)
- 40 ~ 160mbar ( DN40 ~ 250 ) |
GIK 15 to 50...,GI 65 to 150... |
Air/gas ratio controls |
|
The air/gas ratio controls serve to maintian a constant air-gas ratio
and to regulate the gas pressure upstream of gas burner
on installations without preheated combustion air.
Inlet 200mbar /outlet pressure 1 : 1
- ( Rp1/2 ~ 2 )
- ( DN65 ~ 150 ) |
VGP 10 to 25... |
Solenoid valves for gas |
|
Safaty valves for gas with spring-loaded valve disc for
safeguarding and controlling the gas and air supply to
gas burners.
Max inlet 150 ~ 200mbar
- ( Rp3/8 ~ 1 ) |
VG 15 to 40R.. , VG 40 to 65F.. |
2-step solenoid valves for gas |
|
For the protection, shut-off and release of the air and gas
supply to gas burner and gas devices with two-step operation.
Max inlet pressure130, 360mbar
- ( Rp1/2 ~ 1 1/2 )
- ( DN40 ~ 65 ) |
VAN 15 to 40 R... |
Solenoid relief valve
|

|
For soundness proving of gas armatures in conjunction with
a visual discharge unit.
Max inlet pressure 200, 1000mbar
- ( Rp1/2 ~ 1 1/2) |
DKG 25 to 150...,DKL25 to 150...,DKR15 to 500... |
Butterfly valves |
|
Butterfly valves are used to set thr flow rate of air and gas on
gas burner. With attached gear motor.
Max inlet pressure 300mbar
- ( DN15 ~ 150 ) for gas
- ( DN15 ~ 150 ) for air
- ( DN15 ~ 500 ) for air and flue gas |
GT 31...,GT 50... |
Gear motors |
|
For all applications requiring precise and controlled roary
movement between 0 and 90 degrees or 0 and 160 degrees
with three-point step control. |
VS ... N, L |
Solenoid valves for gas
|
|
Gas safety valves with spring-loaded valve disc for safeguarding and
controlling the gas ans air supply to gas burners and gas devices.
The modular construction principle of the flow bodies permits individual
assembly with all components of the MODULINE range.
- ( Rp 3/8 ~ 2 ) max pressure 200mbar |
DG ...B, U, H, N |
Presure switch for gas |
|
Control of gas and air pressure in negative pressure cut-out
for low voltage.
- 0.4 ~ 500mbar ( Rp1/4 ) |
IFS 244,IFS 258 |
Automatic burner control u |
|
It is used on burners with mechanical combustion air supply systems,
on which a separate logic system controls the blower, and
on atmospheric burner.
|
IFS 132B,IFS 135B,IFS 137B |
Automatic burner control unit
|
|
Suitable for the ignition and control of gas burners in gas firing
installations of all types. Flame control by ionisation probe or UV-cell.
|
BCU400 ...B1 |
Burner control units for PROFIBUS-DP
|
|
Simple trasmission of control signals and backsignals
via a field bus line. |
UVS 1, 5, 6 |
|
|
High sensitive but insensitive to sunlight, daylight, infra-red radiation
and filament lamps to protected againt interruptions or short circuits
in the flame signal line.
|
TZI ...,TGI ... |
|
|
Igniotion transformers for high-voltage ignition of gas burners and
gas-ignited or directry ignited oil burner.
input 115, 230V. / output 5, 7kV.
|
ZAI ... |
|
|
For the safe ignition and flame protection of atmospheric burner
in conjunction with our automatic burner controls IFS... |
ZMI ...B ... |
|
|
For the automatic ignition and control of gas burner, in conjunction
with the automatic burner controls IFS or PFS and the ignition
transformer TZI or TGI. |
ZIO ...,BIO ...,BIC ... |
|
|
On industrial furnaces and kilns and gas fired installations in
the precious-metals, nonferrousmetals and light-alloys sector.
|
DM ...R, Z...,DE ...R, Z... |
Flow meters |
|
For measuring gas and air quantities and the current throughput.
Typical applications include secondary measurement of
the consumption in industrail installations. In particular for
monitoring and setting up of burner in gas appliances.
Measuring range : 1.6 ~ 1600m3/h.
- Mecanical counter head
- Electronic counter head |